Electrical characteristics, Electrical connections – Burkert Type 8081 User Manual

Page 14

Advertising
background image

14

Type 8081

english

Technicaldata

6.3.3.

electrical characteristics

Supply voltage (V+)

12-36 VDC

Current consumption • Own consumption: < 4 mA

• Consumption with load: < 1A

Pulse output
(transistor)

• version without

current output

• version with cur-

rent output

• NPN as default setting; (PNP on

request), open collector, 5 mA min.,
700 mA max., NPN output: 0,2-36 VDC

• PNP as default setting; (on request:

NPN for the pulse output and sink-
ing mode for the current output), open
collector, 5 mA min., 700 mA max.,
PNP output: supply voltage (V+)

If QN=0.6 or 1.5: 1 pulse corresponds
to a volume V = 0.002 l (K factor =
500 pulse/litre)
If QN=2.5 or 3.5: 1 pulse corresponds
to a volume V = 0.005 l (K factor =
200 pulse/litre)
If QN=6: 1 pulse corresponds to
a volume V = 0.01 l (K factor =
100 pulse/litre)

Current output

4-20 mA (sourcing mode as default set-
ting; on request: sinking mode for the cur-
rent output and NPN for the pulse output)
corresponding to the flow rate range of
the selected model (default setting) or to a
temperature range (on request)

max. loop resistance :
1100 W at 36 V DC
610 W at 24 V DC
100 W at 12 V DC

Protection against:
reversed polarity
voltage peaks
short-circuits


yes
yes
yes, for the pulse output

Recommended cable
type


max. cross section of 1.5 mm

2

6.3.4.

electrical connections

flow rate meter
version

type of cable plug

Any version

female 5-pin M12 cable plug (available as an
accessory; Order code 438680)

Advertising