Appendix b. glossary – Fluid Components International FLT Series Rack Mount User Manual

Page 24

Advertising
background image

Doc. No. 06EN003250 Rev. N/C

B - 1

FLT

Series FlexSwitch

Rack Mount

APPENDIX B - GLOSSARY

FLUID COMPONENTS INTL

ABBREVIATIONS

Delta-R (

∆R)

Differential Resistance

Delta-T

(∆T)

Differential Temperature

DMM

Digital Multimeter

DPDT

Double Pole Double Throw

F C I

Fluid Components Intl

HTR

Heater

LED

Light Emitting Diode

POT

Potentiometer

RA

Return Authorization

RTD

Resistance Temperature Detector

SFPS

Standard Feet Per Second

SPDT

Single Pole Double Throw

DEFINITIONS

Active RTD

The of the sensing element that is heated by the heater. The active RTD
is cooled due to increases in the process fluid flow rate or density (level sensing).

Differential resistance
Delta-R (

∆R)

The difference in resistance between the active and reference RTDs.

Differential temperature
Delta-T (

∆T)

The difference in temperature between the active and reference RTDs.

Heater (HTR)

The part of the sensing element that heats the active RTD.

Local enclosure

The enclosure attached to the sensing element.

Reference RTD

The part of the sensing element that senses the process media temperature.

Resistance Temperature
Detector (RTD)

A sensor whose resistance changes proportionally to temperature changes.

Sensing element

The transducer portion of the instrument. The sensing element produces
an electrical signal that is related to the flow rate, density (level sensing), and
temperature of the process media.

Thermowell

The part of the sensing element that protects the heater and RTDs
from the process fluid.

Turndown

The ratio of the upper to lower flow rate values.

Appendix B. Glossary