Fluid Components International CMF Series Manual Installation of Electronics User Manual
Page 7
In
st
allation of signal con.
Fluid Components Intl
Document 06EN003327 Rev. -
37
FlexCOR
™
Model CMF Series
5.2.5 Installation in wall
mounting enclosure
1. Mount the enclosure to the wall with four screws.
2. Mount the SENSORPROM
®
unit on the connection board as shown.
The SENSORPROM
®
unit is supplied with the sensor in the terminal box. The
connection board for IP 65 wall mounting boxes must be used.
3. Connect the cables to the terminals, see "Electrical connection".
4. Plug in the transmitter and close the cover.
5.2.6 Installation in the
back of a panel
1. Mount the SENSORPROM
®
unit on the connection board as shown.
The SENSORPROM
®
unit is supplied with the sensor.
2. Mount the connection board in the back of the enclosure.
3. Connect the cables as shown under "Electrical connection".
4. Mount the enclosure in the back of a panel with four screws.
5. Plug in the transmitter.