10 LMC-64 metering card

The Level Meter Card (LMC-64) interface card enables the Eclipse HX-Delta to provide audio level
metering for Production Maestro Pro over a network.

Each LMC-64 interface card can meter up to 64 virtual partylines (conferences) and four-wire
ports
.

The LMC-64 interface comprises:

• A front card with a reset button and various status indicators (including status LEDs for power,

port activity and LAN status).

Note:

The port activity LEDs are inactive on the LMC-64 front card as the E1/T1 ports are not
used.

• A rear card with eleven RJ45 ports giving eight E1/T1 ports (not used), DECT sync in and out

(not used) and a LAN port used for the IP connection.

Note:

An Ethernet cable must be connected to the LMC-64 interface LAN port for the card to function
correctly.