12.3 Environmental

Category

Measures / comments

Operating Temperature

0º C to +40º C, ambient

Storage Temperature

-55º C to +70º C

Humidity, Maximum

90% non-condensing

Table 29: Environmental

12.4 Matrix performance

Category

Measures / Comments

Sample Rate

48 kHz

Resolution

24 bit

Frequency Response
@ 48 kHz sampling

30 Hz – 22 kHz ± 3 dBu

Crosstalk (adjacent channel)

<–70 dBu

Nominal Level

0 dBu

Matrix headroom

+18 dBu

Distortion

<0.05 %, @ 0 dBu, 300 Hz to 10 kHz;

<0.1 %, @ 0 dBu, 100 Hz to 20 kHz

Off Noise

<–70 dBu (20 Hz - 22kHz)

On Noise

<–65 dBu (20 Hz - 22 kHz)

Key Response, Intra-System

<40 ms for audio route

Table 30: Matrix capabilities

12.5 E-MADI64 interface front card

Category

Measures / comments

Height

6RU

Depth

300 mm

Operating Temperature

0º C to +40º C

Storage Temperature

-55º C to +70º C

Humidity

40 - 90% non-condensing

Power

+3.3V

Table 31: E-MADI64 interface front card