7 power status and alarm lights, 1 power status light [power good, Power status and alarm lights – Clear-Com HX System Frames User Manual

Page 65: Power status light [power good

Advertising
background image


D

VOX Lights

When lit a VOX light indicates that the audio level on a connected device,
such as an intercom panel or interface, has exceeded a preset threshold. The
threshold audio level is set through the EHX application.

Each of the port card’s 16

green

VOX lights corresponds to one of 16 rear-

panel connectors or “ports” to which audio devices (intercom panels or
interfaces) can be connected.

E

Matrix Data Light

The

green

matrix data light flashes (1: 1 0.5Hz) to indicate successful

communication between the port card and the CPU card.

Status Light

The

red

status light illuminates to indicate a failure in communication

between the port card and the CPU card.

Table 14: Key to MVX-A16 analog front panel lights and controls

5.7 Power status and alarm lights

Tip:

The location of the power status lights, the alarm lights and the reset button are shown in


Figure 2: Eclipse HX-Delta front
panel.

The front panel of the Eclipse HX-Delta displays power status and alarm lights.

An alarm source turns on the main alarm light [Alarm] (and an audible warning) and one of
the alarm lights dedicated to a specific alarm condition. This enables you to identify or
correct alarm conditions before they affect the operation of the matrix.

Under normal operating conditions, the

red

front-panel alarm lights stay off, while the

green

power supply light stays on continuously.

5.7.1 Power status light [Power Good]

When lit, the

green

power status [Power Good] light indicates that the matrix is receiving

sufficient power from either of the two external 12V power supplies.

65

Eclipse HX-Delta User Guide

Advertising
This manual is related to the following products: