Hardware installation – CTI Products EXB Network Manager User Manual

Page 13

Advertising
background image

Hot-Standby EXB / Network Manager Software Manual

Hardware

CTI Products, Inc.

Installation

9

68-11707-100

3. Hardware Installation

3.1 MCN Hardware (EXB Modules) Installation

Hardware must be installed in accordance with the following documents which
are listed from most system-specific to most generic. In the case of any
discrepancy, the documents first in the list shall take precedence.

1. Customer Specific System Diagrams and Configuration Documents

CA-xxxxx-xxx

Drawings

KA-8xxxx-xxx

Custom Configuration Disks

2. MCN Monitoring and Control Network

Engineered System Installation Manual

Part Number S2-60650

3. MCN EXB Network Extender Manual

Part Number S2-60596

4. Monitoring and Control Network System Manual

Part Number S2-60425

Since all EXB modules have custom addresses, they must be installed as per the
customer specific documents.

If a system is pre-configured at the factory, the EXB modules will be labeled
appropriately.

If a system is not pre-configured, the EXB modules must each be programmed
appropriately with the custom scripts provided in the Customer Configuration
Disk(s). See the instructions with the Customer Specific System Drawings.

When Serial EXB modules are used, be sure to set the Baud Rate switches on the
back of the units to the WAL Line data rate being used. 19.2K or higher is
recommended. Be sure to use Asynchronous Serial channels for the WAN line.

When Analog (Telco) EXB units are used, be sure to set the wireline 2W/4W ,TX
Level (-10 / -16 dBm), and Answer/Originate option switches as appropriate (see
Customer Specific information and the EXB manual.)

3.2 Serial EXB Dual Port Use

Serial EXBs have two serial ports. The following rules govern the use of those
ports:

1. Remote EXBs (CIB EXBs) can use 1 or 2 ports. They can feed

multiple MCNRCD display positions. If two EXB Network
Management Software PCs are running, both can see this remote EXB.

2. Central EXBs can use only 1 port.