CTI Products EXB Network Manager User Manual

Page 38

Advertising
background image

Hot-Standby EXB / Network Manager Software Manual

Network Manager

CTI Products, Inc.

Program Operation

34

68-11707-100

6.8.4 Remote Main EXB Failed

Figure 30 Remote Main EXB Failed

Since the loop is not complete, the Standby EXB turns on its network switch to
pass traffic over the Standby WAN line.

In this condition, the program can talk to the units as follows:

EXB

Forward
(Clockwise)

Reverse
(Counter-Clockwise)

Main (Central)

Yes

No

Standby (Central)

No

Yes

Remote Standby

No

Yes

Remote Main

No

No

Based upon this, the program determines that the Remote Main EXB unit is bad.

Other possible causes for this display could be:

1. No power to the Remote Main EXB module.

2. A bad Main WAN line AND a bad Remote tie line.

(Highly unlikely that two failures have occurred.)

However, the program flags these lines as questionable since it cannot
determine that they are good.