Program Operation
37
68-11707-100
6.8.7 Remote Standby EXB Failed
Figure 33 Remote Standby EXB Failed
Since the loop is not complete, the Standby EXB turns on its network switch to
pass traffic over the Standby WAN line.
In this condition, the program can talk to the units as follows:
EXB
Forward
(Clockwise)
Reverse
(Counter-Clockwise)
Main (Central)
Yes
No
Remote Main
Yes
No
Standby (Central)
No
Yes
Remote Standby
No
No
Based upon this, the program determines that the Remote Standby EXB unit is
bad.
Other possible causes for this display could be:
1. No power to the Remote Standby Main EXB module.
2. A bad Standby WAN line AND a bad Remote tie line.
(Highly unlikely that two failures have occurred.)
However, the program flags these lines as questionable since it cannot