Hot-Standby EXB / Network Manager Software Manual

Network Manager

CTI Products, Inc.

Program Operation

40

68-11707-100

6.8.10 Central Tie Line Bad

Figure 36 Central Tie Line Bad

Since the loop is not complete, the Standby EXB turns on its network switch to
pass traffic over the Standby WAN line.

In this condition, the program can talk to the units as follows:

EXB

Forward
(Clockwise)

Reverse
(Counter-Clockwise)

Main (Central)

Yes

No

Remote Main

Yes

No

Remote Standby

Yes

No

Standby (Central)

Yes

No

Based upon this, the program determines that the Central Tie Line to the Standby
EXB unit is bad.

Note that if the MCNRCD PCs at the central site are connected to the Standby
EXB, they may actually be receiving data via the Standby path.

Other possible causes for this display could be:

1. Bad MCN Network port on the Standby EXB unit.

Advertising