TYPICAL INSTALLATION

INSTALL EMERGENCY DISCONNECT SYSTEM

Floor

2'

4' above

floor

Wrap hand chain around hand chain wheel and through chain
guide.

Secure chain retaining bracket to wall 4 feet above the floor.

Connect the ends of the hand chain.

Hand
Chain

Hand Chain
Wheel

The MHS operator includes both a floor level disconnect sash
chain to disconnect the door from the door operator that allows
manual push up operation and an additional sash chain to engage
the manual chain hoist that also electrically disables the operator
controls.

Keyhole Bracket

Chain Retaining
Bracket
(with pad locking
provisions)

Secure keyhole bracket to wall 4 feet above the floor.

MODELS MH AND MHS ONLY

MODELS MJ AND MGJ ONLY

1

1

2

3

4'