Photoelectric Sensor

ALTERNATE INSTALLATION: C2 WIRING TYPE WITH MONITORED
ENTRAPMENT PROTECTION DEVICE

• Momentary contact to open and stop with constant pressure to

close.

• Open override that reverses when closing by any opening

device.

• Wiring for entrapment protection device to reverse.

NOTE: The operator will automatically convert to B2 wiring when
Monitored Entrapment Protection Device is installed.
(See accessories page for Monitored Entrapment Protection
Devices.)

• Timer-to-Close (TTC) feature not available.

Press and hold the LEARN and CLOSE buttons until the LED
goes out (approximately 3 seconds).

Press and hold the LEARN and STOP buttons until the LED
goes out (approximately 3 seconds).

MONITORED ENTRAPMENT PROTECTION DEVICE

To Program:

To Reset to B2 with Monitored Entrapment Protection Device:

TTC

LED

AUX ANT

R27

L5

TP1

C20

C9

C29
R24

J2

C21

J4

K2

LT

P1

C32

U4

D7

D6

D5

D4

R25

U1

C31

D14

C18

014A1030

^^^^

D9

LEARN

1

2

3

4

5

6

7

LMEP1

LMEP2

INTRLK

COM

STOP

CLOSE

OPEN

STOP CLOSE OPEN

AUX ANT

Logic Board

Electrical Box

D14

LED

LEARN

1

2

3

4

5

6

7

STOP

CLOSE

OPEN

ALTERNATE INSTALLATION: C2 WIRING TYPE WITHOUT
MONITORED ENTRAPMENT PROTECTION DEVICE

(FACTORY DEFAULT)

• Momentary contact to open and stop with constant pressure to

close.

• Open override that reverses when closing by any opening

device.

• Wiring for entrapment protection device to reverse.

NOTE: The operator will automatically convert to B2 wiring when
Monitored Entrapment Protection Device is installed.
(See accessories page for Monitored Entrapment Protection
Devices.)

• Timer-to-Close (TTC) feature not available.

NON-MONITORED ENTRAPMENT PROTECTION DEVICE

Sensing Edge

Remove any monitored entrapment protection devices.

Turn the main power OFF and then ON to restore the operator
to the FACTORY DEFAULT setting.

Reset to FACTORY DEFAULT (C2) when the Monitored
Entrapment Protection Device has been learned and then
removed:

1

1

1

2

BASIC PROGRAMMING

DETERMINE THE WIRING TYPE

REMOTE CONTROLS

RADIO OPERATION

MODE

OPEN

CLOSE

STOP

REVERSE WHILE CLOSING

TTC RESET

B2

X X X

X

B2 with TTC

X

X (3-button remote)

X

X

X when open

C2

X X

X

Advertising
This manual is related to the following products: