Control connection diagram – Controlled Products Systems Group CDO MD L/H Hoist 1/2hp 115v User Manual

Page 28

Advertising
background image

© 2011, The Chamberlain Group, Inc.

01-34213E

All Rights Reserved

IMPORTANT NOTES:
1. The 3-Button Control Station provided must be connected for operation.
2. If a STOP button is not used, a jumper must be placed between terminals 3 and 5.
3. If INTERLOCK is not used a jumper must be placed between terminals 3 and 4.
4. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation
with the Commercial Door Operator.

3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON

2 OR MORE

KEY LOCKOUT

7

6

3

5

Stop

Close

Open

Stop

Close

Open

7

6

3

5

Stop

Close

Open

2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER

STANDARD

7

6

3

Close

Open

C2

MODE ONLY

2 OR MORE

7

6

3

Close

Open

Close

Open

C2

MODE ONLY

DEVICE TO REVERSE

EXTERNAL INTERLOCK

1

2

3

4

3

4

Remove Factory Installed Jumper

When Interlock is Used

ONE

2 OR MORE

STANDARD

7

6

3

5

Stop

Close

Open

All Wiring Types

Keyswitch

Sensing Device

Note: For photoelectric sensors connection options see
ENTRAPMENT PROTECTION section.

See note 2.

See note 2.

CONTROL CONNECTION DIAGRAM