Basic programming, Determine the wiring type – Controlled Products Systems Group CDO MD L/H Hoist 1/2hp 115v User Manual

Page 20

Advertising
background image

20

DETERMINE THE WIRING TYPE

The functionality of this operator is based on the wiring type. The operator is shipped from the factory in standard C2 wiring type
(factory default). LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICE IS RECOMMENDED.

A LiftMaster Entrapment Protection (LMEP) device is required for any momentary contact to close mode of operation including B2,
TTC and remote controls.

NOTES:

The LED on the logic board will blink once when in C2 and twice when in B2.

The operator will automatically convert to B2 wiring when Monitored Entrapment Protection Device is installed. If the Monitored

Entrapment Protection Device is blocked or removed, the operator will go into a Restricted Close mode**.

** Restricted close mode requires a constant pressure close command. The operator will begin closing after a 5 second delay and

will continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close
limit.

RECOMMENDED INSTALLATION: B2 WIRING TYPE WITH
MONITORED ENTRAPMENT PROTECTION DEVICE

• Momentary contact to open, close and stop.

• Open override that reverses when closing by any opening

device.

• Wiring for entrapment protection device to reverse.

NOTE: The operator will automatically convert to B2 wiring
when Monitored Entrapment Protection Device is installed.
(See accessories page for Monitored Entrapment Protection
Devices.)

• Timer-to-Close (TTC) feature available.

Photoelectric Sensor

MONITORED ENTRAPMENT PROTECTION DEVICE

BASIC PROGRAMMING

No Programming Required

Advertising