Controlled Products Systems Group 26SASM User Manual

Page 12

Advertising
background image

DOOR UNLOCK MODE. The relay may be set to stay latched (door
unlocked) during periods when access control is unwanted. While in
the “DOOR UNLOCK” mode, the relay stays activated, and the LED
indicator will flash green approximately once every second. The
unit may not be programmed with the programming deck, nor will it
recognize access cards while in the “DOOR UNLOCK” mode. To set
the unit to the “DOOR UNLOCK” mode, place the “*” (THRU) card on

the TOUCH CARD

®

reader plate, remove it and place the “ACTIVE/

INACTIVE” card on the TOUCH CARD

®

reader plate and remove it.

*

+ ACTIVE/INACTIVE

To return the ENTRACOMP

®

26SA to normal operation, place the “ACTIVE/

INACTIVE” card on the TOUCH CARD

®

reader plate and remove it.

TIMED ANTIPASSBACK FEATURE. If the Timed Antipassback feature
is activated, a card used for entry is made temporarily void for a settable
amount of waiting time. The purpose of this feature is to deter a user
from “passing back” his card to another for unauthorized entry. Once
activated, you must set an antipassback waiting time for this feature to
be functional.

To activate the Timed Antipassback feature, place the “*” (THRU) card
on the TOUCH CARD

®

reader plate and remove it. Then place the

“SET TIMER” card on the TOUCH CARD

®

reader plate and remove

it. Then place the “VALID” card on the TOUCH CARD

®

reader plate

and remove it.

*

+ SET TIMER + VALID

Secura Key • 8