4. Connect power and control lines to wire leads provided as

per the wiring instructions.

5. Plug connector into reader board.

6. Place ENTRACOMP

®

26SA housing over mounting bracket.

Push housing in against wall. Secure housing to mounting
bracket in door opening using two 6-32 x 3/8 screws
provided. Secure housing to bracket at bottom using one
6-32 x 1/4 security screw provided or equivalent.

7. Place housing door into door opening and rotate key 90

degrees clockwise.

METAL SURFACE HOUSING WITH FLANGE ADAPTER
(See Figure 14)

1. Position flange mount adapter (optional) against post flange

(not supplied). Locate and mark four (untapped) holes. Then
drill and tap four 10-32 holes in post flange.

2. Apply silicone bead around perimeter of post flange. Place

flange mount adapter against post flange and secure with
four 10-32 x 1/2 flat head countersunk screws provided.

3. Follow instructions 2 - 7 for post mount adapter.