SPECIFICATIONS

PHYSICAL

Surface Housing Flush Housing

Metal Housing

Depth

2.25 in (5.72 cm)

1.50 in (3.8 cm)

1.75 in (4.45 cm)

Width

4.00 in (10.16 cm)

5.50 in (13.97 cm)

4.00 in (10.20 cm)

Height

4.60 in (11.70 cm)

7.63 in (19.38 cm)

5.62 in (14.30 cm)

Weight

20 oz (0.57 kg)

18 oz (0.51 kg)

45 oz (1.28 kg)

Material Lexan

7

(Polycarbonate) meets UL standard

All Steel

94 flame retardant rating

POWER REQUIREMENTS

10 to 24 VAC, 70 mA , 50 or 60 Hz or 10 to 24 VDC, 70 mA

OUTPUTS
Latch

SPST contact, 1A up to 60 VAC or DC

Tamper (optional)

SPDT contact, 115 VAC, 2A maximum

INPUTS
Remote Open (REX)

Close circuit to operate Latch Relay

ENVIRONMENT
Ambient Temperature

-40

o

F to 158

o

F (-40

o

C to 70

o

C)

Humidity

0% to 95% relative humidity (non-condensing)

OPERATIONAL
Memory

E

2

PROM (non-volatile)

Card Capacity

65,503 cards

Facility Code

Up to 10 different codes simultaneously

Latch Relay

Programmable from 1 to 99 seconds

Timed Antipassback

Programmable from 1 to 99 minutes

This product complies with UL 294 standards.