Setup and operation using lcd, Resetting to factory defaults, System setup checklist – Lectrosonics VRFIELD (Narrowband) User Manual

Page 10: Locate clear channels

Advertising
background image

VR Field

Setup and Operation Using LCD

Use the following procedures to setup and operate the

VR Field System using the front panel LCD, pushbut­

tons and controls.
These procedures assume there is at least one receiver

module installed and that receiver module is installed in

Slot 1. If there is at least one receiver module installed,

but it is not in Slot 1, then use the lowest numbered

slot where a receiver module is installed as the starting

point for the following procedures.
For detailed information on the functions and setup

screens used for these procedures, refer to the VR

Field System Reference Manual.

Resetting to Factory Defaults

Resetting to Factory Defaults can be of great benefit

when everything is going wrong and it’s time to start

back at the beginning. This is done by powering off the

VR Field System, then pressing and holding Receiver

Select buttons 5 and 6 while powering up the system.

POWER.Switch

Receiver.Select.

Buttons.5.and.6

The Factory Default Settings are:
SetUpRx. Level

+00 dBu

Phase

NORMAL

TxBatt

9V ALK

SmartNR

NORMAL

PilotBP

NORMAL

Compat

Dig. Hybrid

Tuning

NORMAL MODE

DivMode

Switched

LockSet

Lockset

NOT LOCKED

System Setup Checklist

The following steps are needed to set up the system.
1. Locate Clear Channels
2. Set Diversity Modes
3. Set Compat Mode, Audio Levels, Battery Status

Monitoring and Noise Reduction Mode

4. Set Transmitters to Match Receiver Frequencies
5. Adjust Audio Output Levels
6. Conduct a Walk Test

Locate Clear Channels

Finding clear operating frequencies for multiple channel

receivers, such as the VR Field System, is a bit more

complicated than single channel receivers. This is due

to intermodulation, or interference from other transmit­

ters. Minimizing this problem is critical to ensure quality

audio. Regardless of which procedure is used to locate

a clear channel, the clear channels discovered need

to be compared with those listed on the Compatible

Frequency Chart to ensure minimal intermodulation

problems. (See Frequency Coordination.)

Using a Tuning Group to Locate Clear Frequencies

1. Turn all transmitters OFF. Then press Receiver

Select Button “1” (below the LCD) to access the

receiver detail screen.

2. Press the MENU/SELECT control, the rotate the

knob to select Tuning. Press the knob again to enter

the Tuning Setup screen. Rotate the knob while

observing the LCD, then select “GROUP a.” The

letters “G A” will appear in the small box in the lower

left part of the LCD. Press the BACK button twice to

return to the receiver detail screen.

5. Observe the RF signal strength meter on the LCD

and rotate the MENU/SELECT control through the

eight preselected frequencies and find one where

no RF signal is present. Any signal displayed

indicates RF Interference. No RF signal strength

indicates a clear channel.

6. If no clear frequency can be found, try using

“GROUP b” and repeat the procedure above.

RF.Signal.Strength.Meter.

(strong.signal.being.received)

7. Continue this procedure for the other receivers.

Leave all transmitters OFF.

NOTE: Review the chapter on Frequency

Coordination near the back of this manual for more

details on compatibility between frequency groups.

LECTROSONICS, INC.

10

Advertising