Walk test recorder, Factory defaults, Delete vr – Lectrosonics VRFIELD (Narrowband) User Manual

Page 21

Advertising
background image

Digital Hybrid Wireless™ Modular Receiver System

Receivers.1&2.in.Ratio.Diversity.Mode,.Rest.in.

Switched.Diversity.Mode

Cursor.Select

Receiver.Module.

Frequency.Locations.

Clicking

Stop suspends the scan. Clicking Run re­

sumes the scan. Clicking

Clear stops the scan and

clears the spectrum data.

Walk Test Recorder

The Walk Test Recorder offers a convenient method of

testing the operation of the selected receiver module (or

receiver module pair) with their corresponding transmit­

ters. The Walk Test Recorder makes a chart recording

of the RF signal strength aligned with an audio record­

ing of the receiver modules output.

Record.Button

Stop.Button

Use the MC65 cable (supplied with unit) to connect the

PHONES jack output on the VR Field Receiver front

panel to the computer system’s audio input.
Click the Record button to start the Walk Test Recorder

and the Stop button to stop the recording process. It is

suggested to mention locations frequently during this

test to more easily identify problem areas.

Factory Defaults

Clicking this menu item restores the selected VR Field

System to the factory default settings.
The Factory Default Settings are:
SetUpRx. Level

+00 dBu

Phase

NORMAL

TxBatt

9V ALK

SmartNR

NORMAL

PilotBP

NORMAL

Compat

Dig. Hybrid

Tuning

NORMAL MODE

DivMode

Switched

LockSet

Lockset

NOT LOCKED

Delete VR

Clicking the Delete VR menu item deletes the current

VR Field System from the VRpanel.

Rio Rancho, NM

1