Hardware installation, Installing/removing receiver modules, Installing the vr field system – Lectrosonics VRFIELD (Narrowband) User Manual

Page 8: Installing receiver modules, Removing receiver modules

Advertising
background image

VR Field

Hardware Installation

Installing/Removing Receiver Modules

Up to six Receiver Modules can be installed in a VRF

chassis. These modules may be installed at the factory

or added later.
Although the VR Field System is quite flexible, any com­

bination of Receiver Modules installed must be within

the frequency block range of the VRF chassis. The

frequency block range of the VRF chassis is displayed

during the PowerUp Sequence.

Frequency.Block.Range

Installing Receiver Modules

1. Ensure the VR Field System is turned off and the

power source has been disconnected. Slide the

Receiver Module Connector firmly onto the Receiv­

er Module Tab.

Caution: Do not force the Receiver Module

onto the Receiver Module Tab. If the module

does not seat properly, look to see if its

position is a little off. Excessive force may

damage the module’s connector or the

Receiver Module Tab.

2. Install a Receiver Module Retaining Clip between

the rear of the Receiver Module and the Module

Tab. Ensure this clip is firmly snapped into place.

Receiver.Modules

Receiver.Module.Tabs

Receiver.Module.

Receiver.Module.

Retaining.Clips

Connectors

Bottom View of the Chassis

VRF.Front.Panel

VRF.Rear.Panel

Removing Receiver Modules

1. Ensure the VR Field System is turned off and the

power source has been disconnected.

2. Remove the Receiver Module in the reverse order

of installation, i.e., remove the Receiver Module Re­

taining Clip, then slide the module off the Receiver

Module Tab and remove it from the VRF chassis.

Installing the VR Field System

The VR Field Receiver is designed for portable use, as

in a bag system.
1. Position the unit for easy access to the panel con­

trols and connections. There are no special ventila­

tion requirements.

2. Connect the antennas (or antenna cables if remote

antennas are being used) to the antenna input con­

nectors on the rear panel of the VRF.

Coaxial.Cables

Antenna

Inputs

3. For multiple unit installations, connect coaxial patch

cables from the Antenna A and B OUT jacks on the

rear panel of the first unit to the Antenna A and B IN

jacks on the second unit. An additional unit can be

connected to the second unit in the same manner.

Note: All units connected in this manner must be on the same

frequency block.



LECTROSONICS, INC.