A.O. Smith AHD 290 User Manual

Page 39

Advertising
background image

When construction and building the heat pump all relevant EU guidelines have

been followed. (Also see EU-declaration of conformity.)

Any work carried out on this unit may only be done by skilled

personnel. Take all necessary precautions to avoid accidents.

1.1

Scope of delivery

Heat pump with built-in controls

Installation manual with technical data

Operating instructions

1.2

Product description

The AHD 290 is a domestic water heat pump with a condenser on the outside of the

tank. The application area and operating principles of the heat pump are specified

in the operating instructions.

1.3

Technical data

Performance data

Performance specified for heating of domestic water from 15°C to 45°C
Thermal output

(with air 15°C / water 15°C – 45°C)

kW

1,52

Power input

(with air 15°C / water 15°C – 45°C)

kW

0,43

COP

(with air 15°C / water 15°C – 45°C)

3,54

Power consumption electrical cartridge / heating

element

kW

1,5

Operating range / limits

Max. air temperature

°C

35

Max. water temperature

°C

55

Max. water temperature

(with operation of heat pump and electric car-

tridge)

°C

65

Sound level

1 meter in front of unit

dB(A)

52

Domestic water container

Material

Steel specially enamelled

Net volume

l

285

Airflow volume

Airflow volume

m³/h

250

A

1.

About the product

39