54

B

1.

User guide

The AHD 290 comes with a factory setup, which enables an immediate start

of the unit. The factory setup is basic and must be adjusted to the operational

requirements and demands of the individual home, in order to obtain the optimum

operating benefit from the unit.

1.1

Use

User menu

The value of a menu item is shown when pressing the key/key combination

below. The value may be changed with the arrows when the key/key combination

is held down simultaneously. The control will return to standard indication if no

buttons have been pressed for app. 15 seconds.

P1: Heat Pump ON/OFF

On this button it is possible to change the function between:

standby and automatic operation after setpoint P3. (step 0, step 1)

Step 0: The heat pump is now off and only the control is active.

Step 1: The heat pump is in operation mode and drives after

setpoint thermostat P3.

P2: Operation for the electrical cartridge

The heat pump comes with an extra electrical cartridge for heating of

the sanitary hot water. On this button it is possible to turn on the elec-

trical cartridge if required. By adjusting the setpoint to 1 the electrical

cartridge will turn on after setpoint P5 (operating

thermostat for the electrical cartridge). The electrical cartridge is not

on if this setpoint it set to 0.

Note! When the ambient temperature is under 8°C or over 35°C the

electrical cartridge will turn on even if P2 = 0.

P3: Operating thermostat for heat pump

The required sanitary water temperature may be set between

0 - 55°C, which is heated up by the heat pump.

Factory setting: 52°C

Max. water temperature: 55°C

P4: Stop defrosting

The level and operating thermostat buttons are pressed simultaneous-

ly

As a standard setting, the defrosting period ends when the tempera-

ture has reached 10°C. During extraordinary operating conditions, it

may be necessary to change this temperature. The temperature may

be adjusted between 0-25°C.

Factory setting: 10°C

+