Overview

1998 MotorVac Technologies,

xxxiv

Appendix A - Maintenance


Maintenance Procedures


The following maintenance procedures should be performed on a routine basis:

1.

Drain the unit’s

fuel reservoir and replace the fuel filter after every 30 cleaning services, as

described in the next section.

2.

Clean the exterior with a non-abrasive cleaning agent or similar product to keep the cabinet
looking new. Check the cabinet for dents or impact markings.

3.

Check all hoses and wires for cuts or frays.


Replacing the LE-1 Fuel Filter


The unit’s fuel reservoir should be drained and the fuel filter replaced after every 30 cleanings to ensure
maximum system performance and pump life.

Drain the Fuel Reservoir

1.

Turn

the

Pressure Adjust

regulator on the control panel clockwise until it is completely closed.


2.

Attach the unit to the vehicle's battery by connecting the

red

battery clip to the positive (

+

)

battery terminal and the

black

battery clip to a solid ground point as far from the battery as

possible. Turn on the

LE-1

power

switch.

3.

Connect the #060-1400 adaptor to the output (

red

) hose, then drain the gasoline from the unit’s

fuel reservoir using the following procedure:

• Set the

Time

until it displays five minutes.

• Direct the output (

red

) hose into an appropriate container.

• Press and hold the

Start/Run

switch until the fuel from the unit

has been emptied into the

container.

• Release the

Start/Run

switch.

• Turn the

Pressure Adjust Regulator

counterclockwise until completely open to relieve any

residual pressure.

4.

Enter your initials, the date, and a check mark in the appropriate boxes of the Maintenance
Record at the end of this chapter.