LE-1 Features and Functions


Descriptions of the gauge, control switches, and status indicators that make up the control panel are listed
below. Please become familiar with these control panel features and functions before using the unit.

Adjust Time Knob

Sets or re-sets the system run time in one-minute increments, from 1
to 60 minutes.

Start/Run Switch

Starts the cleaning cycle.

Run Cycle Light

Illuminates when the run cycle is under way.

Fuel Pressure Gauge

Displays output pressure of the unit’s output hose, or system
pressure of the vehicle being serviced.

Pressure Adjust
Regulator

Used to adjust the system pressure during the cleaning process. Turn
clockwise to close (increase the pressure); counterclockwise to open
(decrease the pressure).

Warning Alarm

Sounds when the run cycle is complete or when a pressure loss
occurs.

Power Switch

Shuts off power to the unit.

Output Hose (red)

Connects to the input side of the vehicle's engine fuel system.

Return Hose (black)

Connects to the return side of the vehicle's engine fuel system.

Fuel Filter

Filters out contaminants that become removed during the cleaning
process. See Appendix A for replacement information

Battery Cables

Positive (red) and negative (black) battery connections (11-15
VOLTS DC)