Purging air from the system ( priming ) – MotorVac CarbonClean Dual System MCS 352 User Manual

Page 36

Advertising
background image

Purging Air from the System (Priming)

It will be necessary to purge the air from the unit’s plumbing prior to connecting to the engine’s fuel
system.

1

. Connect

the

OUTPUT (RED)

hose and the

RETURN (BLACK)

hose together using

adapters 060-1400 and 060-1100, as shown in

FIGURE B

below. Secure with hose

clamp.

2

. Press

SERVICE SELECTOR

switch to

DIESEL FUEL SYSTEM SERVICE.

Turn

TIMER

past 5 minutes. Press

ON/OFF

switch to on. Press and hold the

START/RUN

switch.

Operate the system in

PRIME

mode for one minute, and then release the

START/RUN

switch. The unit’s filter and hoses should now be purged of air that could possibly go
in the engine’s fuel system, if this procedure was not performed. Press off the

ON

/OFF

switch.

3.

Disconnect

the

adaptors.

Figure B

Advertising