Diesel cleaning procedures, Soak mode – MotorVac CarbonClean Dual System MCS 352 User Manual

Page 40

Advertising
background image

Diesel Cleaning Procedures

1.

Verify that Mixture, Priming, and Diesel Setup Procedures above have been
completed before continuing.

2.

Press

SERVICE SELECTOR SWITCH

to

DIESEL FUEL SYSTEM

and press the

ON/OFF

switch on after turning

TIMER

past five minutes. NOTE: Alarm will sound until pump

starts.

3.

Press and hold the

START/RUN

switch. The unit will start and the pressure should rise. The

pressure can be checked by observing the

FUEL PRESSURE

gauge.

Check all connections

for leaks and correct as necessary.

4.

Once the pressure has stabilized, release the

START/RUN

switch

.

Then start the engine.

Check for fuel leaks and correct as necessary.

5.

Once the unit and engine are running, the run time can be adjusted. The default run time is 60
minutes.

Soak Mode

Use of the Soak Mode Cycle improves fuel system cleaning results, but it may be
bypassed if a shorter service is desired.

1.

After

20

minutes of operation or half of the run time, whichever is less; a

Soak Mode

can be

initialized.

2. Shut

down

engine. Then press off the unit’s

ON/OFF

switch. NOTE: This will shut

down the pump and fuel supply to engine, so it is very important that engine be shut
down first.

3.

Let fuel mixture soak in engine for at least 15 minutes. Turn

TIMER

past five minutes. Turn

the

ON/OFF

switch on. Press and hold the

START/RUN

switch to restart the unit and build

pressure.

4.

Continue on with the cleaning mode. Reset the

TIMER

to the time last shown before the

Soak Mode

was initialized. Restart the engine. The cleaning cycle will continue for the

remaining run time.

NOTE

Additional Soak Cycles can be initiated by repeating
steps 2 through 4 as many times as needed.

Advertising