Diesel Fuel System Setup Procedures

1.

Start the vehicle and allow the engine to reach normal operating

temperature (if possible).

IMPORTANT

Do not perform the setup or cleaning process
if the vehicle’s engine oil or coolant level is
low. If necessary, add oil and/or coolant to the
vehicle. Stop the cleaning process if the
engine is low on oil or overheats.

2.

Turn the engine OFF

when normal operating temperature has been reached.

3

.

If not already connected, attach the unit to a vehicle’s

12-Volt D.C.

battery by

connecting the

red

battery clip to the positive (

+

) battery terminal and connect the

black

battery clip to a solid ground.

4.

Remove the vehicle's fuel cap to relieve fuel tank pressure, if necessary.

5.

Disconnect the vehicles fuel lines going into the engines supply pump

and the return line coming from the injectors (if applicable). There are
now four open ends to work with:

Supply Line

/ Feed

Return Line

1 - From the tank

3 - From

the fuel
return
line

2 - To the

supply
pump.

4 - To

the tank.

IMPORTANT

Try not to allow excessive fuel loss when connecting
or disconnecting the hoses from the engine or the
engine may be difficult to start.