Troubleshooting and Additional Help

Refer to the list below in the unlikely event that you have problems with your

MCS 352.

Problem:

Solution:

1. The MCS 352 is not operational or

trips breaker immediately.

Polarity is reversed on vehicle battery connection.
Check connections for correct polarity. Check
circuit breaker on the side of the cabinet.

2. Pressure Gauge on the MCS 352

displays maximum pressure upon
start up.

Output and Return hoses may be reversed. Turn

Timer

to zero and check hoses for correct

connection.

3. Rapid loss of fuel from the MCS

352 reservoir.

Return hose connection may be incorrect, allowing
fuel/detergent to return to the vehicle's fuel tank.

4. Start/Run switch is on but

operation does not commence.

Check

Timer

. If no time is set, then turn the

Time

knob to set the run time.

5. The MCS 352 performs poorly.

Check all hoses and wires for cuts or frays.
Check cabinet for dents or impact markings.
Verify that the fuel filter has recently been
replaced. (Refer to the maintenance log in

Appendix A

to view dates of services

performed.)