SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS

(ENGLISH DISPLAY TOUCHPADS)

S O U N D

C A U S E

D I S P L A Y

LOUD, INTERRUPTED

*

Touchpad & External

FIRE ALARM

FIRE

is displayed; zone number of zone in alarm is displayed. If a fire alarm is

manually activated, zone number 95 will be displayed.

LOUD, CONTINUOUS

*

Touchpad & External

BURGLARY/AUDIBLE
EMERGENCY ALARM

ALARM

is displayed. Zone number of zone in alarm is also displayed.

ONE SHORT BEEP
(not repeated)
Touchpad only

a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY

a. READY indicator light comes on.
b. The number of the open protection zone is displayed.

c. Zone numbers of the bypassed protection zones are displayed (one beep is
heard for each zone displayed). Subsequently, BYPASS is displayed.

ONE SHORT BEEP
(once every 40 seconds)
Touchpad only

a. SYSTEM IS IN TEST MODE
b. LOW BATTERY AT A
TRANSMITTER

a. Opened zone numbers will appear.
b. BAT displayed with zone number of transmitter.

TWO SHORT BEEPS
Touchpad only

ARM AWAY

AWAY is displayed. Red ARMED indicator is lit.

THREE SHORT BEEPS
Touchpad only

a. ARM STAY OR INSTANT

b. ZONE OPENED WHILE SYSTEM
IS IN CHIME MODE.

a. STAY or INSTANT is displayed. Red ARMED indicator is lit.

b. CHIME displayed; zone number of open protection zone will be displayed if the
[

] key is pressed.

RAPID BEEPING
Touchpad only

a. TROUBLE
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING FAIL.

a. CHECK

displayed. Zone number of troubled protection zone is displayed.

b. FIRE or ALARM is displayed; zone number of zone in alarm is displayed
c. BAT displayed with no zone ID number.
d. CHECK 70

is displayed.

SLOW BEEPING
Touchpad only

a. EXIT DELAY WARNING (if
programmed)

b. ENTRY DELAY WARNING

a. AWAY is displayed.

b. Exceeding the entry delay time without disarming causes alarm.

* If a bell is used as external sounder, fire alarm is