6.0 Start-up and Adjustment

a.)Thepumpisnormallyself-primingifsuctionliftis5ft(1.5m)

orlessandthestepsbelowarefollowed.

b.)Pumpsareshippedfromthefactorywithwaterinthepump

headtoaidinpriming.

6.1

Output Adjustment Controls

Manual series pump controls are not equipped with pressure

control.

1. Pressure Control Adjustment (if equipped): Pressure control

provides the adjustment of the pump’s pressure capability and

power consumption, reducing heat, pipe shock and pulsation

while increasing pump life. See Section 7.0 after priming for

proper adjustment settings.

2. Speed Adjustment (Upper Knob) (if equipped): Speed control

provides adjustment of the percent of maximum strokes per

minute. Turning this knob clockwise increases stroke frequency

(speed).

3. Stroke Adjustment (Lower Knob): Stroke control provides

adjustment of the percent maximum of solution discharged

during each pump actuation. Turning this knob clockwise

increases solution displacement.

A7 and P7 Only:Whenoperatingthepumpinexternalmode,the

speedcontrolknobshouldbeturnedfullycounter-clockwise .