CAUTION

!

8.2

Calibration Procedure - On-Site

Volumetric Calibration in External Mode

1. Since pump output is governed by an external device such

as Flowmeter-Pulser, Liquitron

Controller, or 4-20 mA

DC signal from an instrument with an LMI Analog-to-

Digital Converter, only the output per stroke may be

calibrated.

2. With pump primed and discharge tubing connected to the

injection point as it would be in normal service, place Foot

Valve Assembly in a graduated container with a volume of

1000 ml or more.

3. Switch pump to Internal mode with Speed Knob set at 100

until air is exhausted from suction line and pump head.

4. Adjust Pressure Control (if desired) - See Section 8.1.

5. Switch pump OFF and note solution level in graduated

container. Refill graduate to a starting point.

6. Switch pump ON and count the number of strokes for

exactly one minute, then switch pump OFF.

7. Note volume pumped during the calibration period of one

minute. Divide into this the number of strokes to determine

the volume of solution pumped per stroke.

Example: 500 ml in 100 strokes = 5.0 ml per stroke.

Multiply this by your expected stroke rate per minute, per hour

or per day and compare with desired output requirements.

8. Adjust Stroke Length Knob (lower knob) to your best estimate

of required correction and repeat calibration procedure.

9.0 Spare Parts Replacement

Routine Maintenance



9.1

Depressurizing the Discharge Line

(For Pumps Equipped with a 3-FV or a 4-FV only)



ALWAYS wear protective clothing, face shield, safety glasses

and gloves when performing any maintenance or replacement

on your pump.