Liquifram

Stroke Setting Chart

Pump Series

Stroke Knob Setting

All AA, B, J, P Series

C10, C11, C12, C70, C71, C72, C76,

90%

C90, C91, C92, E70, E71, E72

C78

50%

C13, C14, C73, C74, C77,

C93, C94, E73, E74

70%

*

Liquifram

on M Series pumps only, must be bottomed completely (turned

all the way in).

Do Not Use Straight Edge

.

6. Grasp the outer edge of the Liquifram

and adjust by screwing

it in or out so that the center of the Liquifram

is flush with

the outside of the spacer edge (see illustration below).

7. Once the Liquifram

is properly positioned, remount the

pump head to the spacer using the four (4) screws. Tighten

in a criss-cross pattern. After one week of operation, recheck

the screws and tighten if necessary.