Troubleshooting, Continued) – Nova-Tech LMI Series AA-B-C-E-J-P Metering Pumps User Manual

Page 43

Advertising
background image

43

SOLUTION

1. Cut about 1 in (25 mm) off tubing and then replace as before.

2. Replace fitting if cracked. Carefully hand tighten fittings.

DO NOT USE

PIPE WRENCH

. Once fitting comes into contact with seal ring, tighten

an additional 1/8 or 1/4 turn.

3. Replace balls and seal rings (see Section 8.3) Spare Parts (SP-#).

4. Consult your local distributor for alternate materials.

1. Injection pressure cannot exceed pump’s maximum pressure. See

pump data plate.

2. Worn seal rings or cartridge valves may need replacement (see Sec-

tion 9.3). Spare Parts (SP- #), or RPM Pro Pac

kit.

3. Replace Liquifram™ (see Section 9.2).

4. Check zero on pump/Re-zero pump (see Section 10.0).

5. Longer tubing runs may create frictional losses sufficient to reduce

pump’s pressure rating. Consult factory for more information.

6. Remove Foot Valve strainer when pumping slurries or when solution

particles cause strainer to clog.

1. Turn on or plug in pump.

2. Disassemble pump and measure the resistance of the EPU across

the EPU wires. Resistance reading should be in accordance to the

EPU Resistance Chart (see Section 12.0). Also, check EPU leads to

ground. Consult supplier or factory.

3. The pulser should be replaced if EPU checks out OK. Consult supplier

or factory.

1. Move injection point to a pressurized location or install an LMI 4-FV

(see Section 4.4).

2. If pressure at injection point is less than 25 psi (1.7 Bar), an LMI 4-FV

should be installed (see Section 4.4).

3. Replace pulser or resistor. Consult factory.

Troubleshooting

(continued)