The wiring diagram in figure 2.1 is numbered. Follow the step below according to the wiring number shown in figure
2.1.

Step 1

CO1, CO2, TN1, and TN2 to 1, 2, 3 and 4.

The Interceptor Module can be installed inside the AeGIS 4000 cabinet or away from it. The interceptor module is
necessary to put the system in Bypass incase of problem or needs repair.

• The maximum distance between the AeGIS 4000 and the Interceptor Module and Home Phone cannot be

exceeded 2200 feet using 18 -gauge 4-conductors shielded stranded wires.
Warning: Longer distance is not recommended.

• Ground one end of the shield into the earth ground or telephone ground block. One common ground is

recommended.

• If the Interceptor Module is inside the AeGIS 4000 cabinet, 22-gauge 4-conductors stranded wires can be used.

Step 2 PHONE CO (Central Office).

Connect to Telephone Central Office or Analog Private Branch Exchanged (PBX). If the AeGIS 4000 is only used
as an Intercom System, skip this step and proceed to Step 3.

• 18-gauge 2-conductors shielded stranded wires are recommended, to avoid static and radio station transmission.
• Ground one end of the shield into the earth ground or telephone ground block. One common ground is

recommended.

Step 3 HOME PHONE

Connect to a Home Phone Set.

• A maximum distance between the AeGIS 4000, Interceptor Module and the Home Phone cannot be exceeded

2200 feet using 18 -gauge 4-conductors shielded stranded wires.
Warning: Longer distance with bigger gauge wires is not recommended. Do not connect Phone Central Office to

Home Phone Terminal.

NOTE: If you install the AeGIS 4000 on dedicated phone for call forwarding only, do not do this step, return to

step2.

Step 4

INTERCEPTOR MODULE GND

Connect to Telephone Ground Block or Earth Ground using 16-gauge stranded wire. One common ground is
recommended.

Step 5

G.

Connect to Telephone Ground Block or Earth Ground using 16-gauge stranded wire. One common ground is
recommended.

Step 6

DOOR 1 STRIKE (Relay 1).

Form C Dry Contact (120 VAC 10A/ 24 VDC 10A/ 250 VAC 7A) Normally Open (N.O) and Normally Closed (N.C).
Connect to Normally Open (N.O) and COM if normally open door strike is used. Door is closed if the strike is not
energized and open if energized.
Connect to Normally Closed (N.C) and COM if normally closed door strike is used. Door is closed if the strike is
energized and open if not energized

• 18-gauge 2-conductors stranded is recommended.

DOOR 2 STRIKE (Relay 2).

Form C Dry Contact (120 VAC 10A/ 24 VDC 10A/ 250 VAC 7A) Normally Open (N.O) and Normally Closed (N.C).
Connect to Normally Open (N.O) and COM if normally open door strike is used. Door is closed if the strike is not
energized and open if energized.

Pach and Company

Page 6

AeGIS 4000

Chapter 2. Installation