Technical Specifications:

Power Input: 12VAC 20VA UL Listed Transformer (Pach supplied) or 12.0 VDC 20VA

Current Consumption: 420mA idle, 620mA operation

Emergency Battery: 12.0 VDC, 4Ahr rechargeable (not supplied)

Night Light: 14V 0.080A 15,000 Average life hours

Telephone Line: Standard voice grade RJ11 jack

Operating Environment: Temp. -32

°F to +140°F Relative Humidity 0% to 95% non-condensing

Relay Output: Two Relays to control two doors independently. Form C Dry Contact 120 VAC 10A/24VDC 10A/250VAC 7A

Memory Type: EEPROM

Tone Detection: Crystal controlled, capable of detecting short bursts 80 ms

Mounting: Surface Mount

Construction: 16 Gauge Stainless Steel

Shipping: 8 lbs. or 3.6 kg. approximate

Dimensions: 9-1/8” (23.2Cm) x 6-15/16” (17.2Cm) x 3-7/8” (9.8Cm) (HWD)

1.5 Options and Accessories

Visit our website www.pach-co.com or call 1-888-678-7224

1.6 Unpacking the System

Check the serial number on the printed circuit board, cabinet and warranty card, they must match. If they do not match,
please contact Pach and Company toll free number at (888) 678-7224. All the items listed below come with the AeGIS 4000
Series.

• AeGIS 4000 Series System.
• XMFR (Power Transformer, 12VAC 20VA).
• Two of 5-pin terminal connector (inside the unit’s cabinet).

• 7-pin terminal connector (inside the unit’s cabinet).
• Key set (2 keys per set)
• Interceptor Module.
• Owners Manual.
• Warranty Card with unit’s serial number.

If you have missing items, please contact Pach and Company at (888) 678-7224.