The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National

Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is

easily accessible in case of an emergency. Arcing

will occur when connecting or disconnecting the

unit unless all controls are in the “

OFF

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed

by a licensed electrician in accordance with

applicable local electrical codes.

230V:

To prevent an electrical shock hazard between

the appliance and other appliances or metal

parts in close vicinity, an equalization bonding

stud is provided. An equalization bonding

lead must be connected to this stud and the

other appliances / metal parts to provide

sufficient protection against potential

difference. The terminal is marked with the

following symbol.

NOTE:

230V appliances must be connected to an

electrical circuit that is protected by an

external GFCI outlet.

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

E L E C T R I C A L - 7 6 7 - S K / I I I

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

AWG

208-240 (

AGCY

) 1

60

16.0

3.85

CORD

at 208

1

60

15.5

3.21

NO PLUG

at 240

1

60

17.8

4.27

230

1

50

16.0

3.68

CEE

7/7

220-230V

PLUG

E L E C T R I C A L - 1 7 6 7 - S K / I I I

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

AWG

208-240 (

AGCY

) 1

60

32.0

7.70

NO CORD

at 208

1

60

30.9

6.43

OR PLUG

at 240

1

60

35.6

8.55

230

1

50

34.1

7.86

NO CORD

OR PLUG

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

D A N G E R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

E L E C T R I C A L - 2 8 0 0 - S K / I I I

VOLTAGE

PHASE

CYCLE

/

HZ AMPS

kW

AWG

208

1

60

43.1

8.96

CORD

,

NO PLUG

240

1

60

38.8

9.31

CORD

,

NO PLUG

230

1

50

37.1

8.54

NO CORD OR PLUG

208

3

60

27

8.96

NO CORD OR PLUG

240

3

60

27

9.31

NO CORD OR PLUG

380-415 (

AGCY

) 3

50

15.5

9.31

NO CORD OR PLUG

PG

. 10

767-SK/III, 1767-SK/III, 2800-SK/III

INSTALLATION

/

OPERATION

/

SERVICE MANUAL

Wire diagrams are located inside the bonnet of the unit.