Error
Code

Description/Results

Possible Cause
Service Required

E-10

Air sensor fault (shorted)

Air sensor is shorted or defective, or there is a connection failure.

See following page for air sensor test.

E-11

Air sensor fault (open)

Air sensor is open or defective, or there is a connection failure.

See following page for air sensor test.

E-20

Product probe fault (shorted)

Oven w ill co o k in tim e o nly

Product probe is shorted or defective, or there is a connection failure.

See following page for probe sensor test.

E-21

Product probe fault (open)

Oven w ill co o k in tim e o nly

Product Probe is open, defective, or there is a connection failure.

See following page for probe sensor test.

E-30

Under temperature

The unit has been below its set temperature for 90 minutes.

Check the following: Oven door may be open or door gasket may need

replacement. Verify that the oven has been preheated, does not contain

frozen products, and is not overloaded. Air sensor, probe, or relay may be

defective, there may be a bad wire connection, an open heating cable, or the

high limit switch may be tripped. Contact service if problem persists.

E-31

Over temperature

This error will display if the unit reaches a temperature of 25 degrees above

its maximum allowable set point. If the unit reaches 50 degrees above its

maximum allowable set point the control will turn off. Check the following:

Shorted cable, defective solid state relay, or defective air sensor. If none of

the above, contact service.

E-50

Temperature sensor chip 1
is not responding.

Contact service.

E-51

Temperature sensor chip 2
is not responding.

Contact service.

E-60

Real time clock error

This is likely caused by the unit having been unplugged for an extended

amount of time. The data stored in the Real-Time Clock has been reset to

the factory default values. Beeper volume will default to on, and the

temperature scale will default to °F. Turn main breaker to the unit off for

10 seconds and then restore power. Contact service if problem persists.

E-61

Real time clock chip is
not responding.

Contact service.

E-70

Configuration connector error

Check control connections for loose wires. If none, control must be replaced.

E-78

Voltage low

Voltage below 90 VAC on a 125 VAC unit, or below 190 VAC on a

208-240 VAC unit. Correct voltage.

E-79

Voltage high

Voltage over 130 VAC on a 125 VAC unit, or over 250 VAC on a

208-240 VAC unit. Correct voltage.

E-80

Function data values were reset.

Ensure that all temperatures and times are properly set.

Contact service if problem persists.

E-81

Internal control calibration error

Contact service.

E-82

Internal control calibration error

Contact service.

E-83

EEPROM is not responding

Contact service.

E-84

EEPROM - Unit ID error

Contact service.

E-86

EEPROM - HACCP address error

If using HACCP, the unit’s address has been reset to 1. Ensure that your

oven is set to the correct address (1-247). Contact service if problem persists.

E-87

Calibration offset error

Sensor calibration values corrupted. All offsets reset to 0. Re-calibrate oven

cavities. Contact service if problem persists.

E-90

Button stuck

A button has been pressed for >= 60 seconds. This error will auto-reset

when there is no button stuck, remove control and check all button

functions, align control properly.

E-dS

Datakey signature bad

Datakey incompatible with control. Incorrect or corrupt data key installed

on control. Replace Datakey with correct key for control and test.

E-dU

Datakey unplugged

The data key is not being seen by the control. Install data key and test

operation. Contact service if problem persists