Introduction, Component identification, Theory – Poweramp CentraAir AIR POWERED 2.2012 User Manual

Page 10

Advertising
background image

8

4111-0023 — Jan. 2012

Component Identification

A — Lip

B — Lip Assist Rod

C —Lip Linkage Assembly

D — Lip Latch Assembly

E — Lip Maintenance Prop Pivot)

F — Lip Actuator Chain Spring

G — Lip Actuator Chain

H — Lip Actuator Chain Adjustment Link

I — Lip Keepers (2 used)

J — Air Bellows

K — Main Frame

L — Maintenance Prop

M —Toe Guard (2 used)

N —Raise Button

O —Safety Legs

P —Air Control Valve

Q —Lanyard

R —Filter/Regulator

The CA dock leveler uses Compressed Air with a lanyard

(single push button) operation for ease of use.

The dock leveler can be operated two different ways. 1.)

RAISE button (N) on the control panel. This activates an

electric solenoid (P). The solenoid allows compressed

air into the air bellows causing the platform to rise.

Releasing the RAISE button allows the platform to lower.
2.) RAISE button (N) on the control panel. This activates

an electric solenoid (P). The solenoid allows compressed

air into the air bellows causing the platform to rise.

Releasing the RAISE button allows the platform to lower.

The regulator supplies 95 psi to the bellows. (P)
When the platform rises to the point where there is

2-3 in. (51-76. mm) from its full raised height, the lip

spring (F) and lip actuator chain (G), causes the lip

linkage assembly to push the lip out and up.

The lip assist spring (not shown) also helps keep the lip

extended. When the lip is fully extended, the lip latch

cable engages the lip latch assembly, locking the lip in

the extended position. The dock leveler has reached its

full height when the lip is fully extended.

To lower the platform, release the lanyard (Q) or

RAISE button (N).

The platform will lower until the extended lip rests on

the truck bed. If the lip did not fully extend or there is

no truck at the dock the platform will lower until one of

the following conditions occur:

• Lip is resting in lip keepers (cross-traffic position).

• Leveler went to the below-dock position, lip folds

automatically, leveler rests on the safety legs

(below dock position).

• Leveler went to the below dock position with

operator holding the safety leg retract cable

(not shown), safety legs are retracted, lip folds

automatically causing dock to rest in the full below

dock position.

THEORY

INTRODUCTION

R

N

Q

P

K

E

D

G

B

A

O

I

J

M

F

L

C