Adjusting Lip Latch Spring Tension

Adjusting Lip Actuator Spring Tension

This adjustment is set at the factory and should not

require additional adjustment.

Unlike mechanical levelers, the lip will not immediately

begin to fold as the platform returns to the stored

position.

The leveler lip remains extended as the platform

drifts down to the below dock position. The lip will

automatically fold when the platform when the dock is

resting on the safety legs in the below dock position

1.) Check air bellows and hoses for possible leaks.

2.) If the lip does not fully extend additional spring

tension may be needed.

NOTE: Use two-turn increments when adjusting lip

assist spring. Check lip operation after each
adjustment. Repeat until proper operation is
obtained.

Adjust spring tension as follows:


a. Loosen jam nut (A).

b. To increase spring tension, turn nut (B) clockwise.

c.

To decrease spring tension, turn nut (B)
counterclockwise.

d. Tighten jam nut.

Recheck operation of platform and lip. Readjust lift

spring tension and lip assist spring tension until proper
operation is obtained.

This adjustment is set at the factory and should not

require additional adjustment.

Unlike mechanical levelers, the lip will not immediately

begin to fold as the platform returns to the stored

position.

After the platform is fully raised, and the lip extends,

the lip latch is designed to hold the lip in the extended

position until the platform drifts down to the below dock

position.

If the lip does not remain extended check proper

engagement of the lip latch.

NOTE: Use two-turn increments when adjusting lip

assist spring. Check lip operation after each

adjustment. Repeat until proper operation is

obtained.

Adjust spring tension as follows:


a. Loosen jam nut (A).

b. To increase spring tension, turn nut (B) clockwise.

c.

To decrease spring tension, turn nut (B)
counterclockwise.

d. Tighten jam nut.

Recheck operation of platform and lip. Readjust lip

latch spring tension and lip assist spring tension until
proper operation is obtained.