Maintenance, Important – Poweramp CentraAir AIR POWERED 2.2012 User Manual

Page 25

Advertising
background image

23

4111-0023 — Jan. 2012

MAINTENANCE

Regular maintenance must be performed on a weekly

and quarterly schedule.

Weekly Maintenance

• Operate the dock leveler through the complete

operating cycle to maintain lubrication.

NOTE: To thoroughly inspect the platform hinge area,

put the platform in the full below-dock position.

• Inspect the platform hinge and the lip hinge areas.

The hinge areas must be kept free of dirt and debris.

Build-up of foreign material in the hinge areas will

cause abnormal operation.

• Inspect the area under the platform, around and

under the air bellows. Build-up of foreign material

in this area may damage air bellows components,

causing abnormal operation.

Quarterly Maintenance

• Perform Weekly Service Items

• Lubricate the following areas with light weight

machine oil:

(A)— Lip hinge area unless equipped with grease

fittings (apply oil to the top of the entire length

of lip hinge when platform is at the full below-

dock position and lip is folded)

(D)— Platform hinge area (apply oil to top of all

platform hinges when platform is at the full

below-dock position)

(E)— Lip lifter and lift cylinder pin

NOTE: Apply grease to lip hinge grease fittings if

equipped.

• Lubricate the following areas with light-weight

machine oil:

(B)— Lip maintenance prop pivot

(C)— Lip link pivots

(F)— Safety leg linkage pivots

• Lubricate the following areas with white lithium

grease (if equipped with grease fittings):

(A)— Lip hinge area (inject grease into all the lip

hinge grease fittings)

(D)— Platform hinge area (inject grease into all the

platform hinge grease fittings)

(E)— Lip assist pin

Before performing any maintenance under the
dock leveler, lock the electrical power source in
OFF position and lock the maintenance prop in the
service position using an approved locking device.
(See Service Dock Leveler Safely in this section.)

Failure to follow these instructions may result in
serious personal injury or death.

IMPORTANT

Failure to properly lubricate the dock leveler will

cause abnormal operation of the leveler.

Advertising