TROUBLESHOOTING

Symptom

Possible Cause

Solution

Platform does not rase

Low Air pressure

Minimum 80 Psi required at regulator, if lower check

air supply.

No voltage to solenoid

Check breakers if ok check voltage at control box and

solenoid

Lanyard Cable Adjustment Check Cable adjustment

Platform rises slowly

Air bladder or connecting air

lines punctured

Check air bladder and air line repair or replace as

needed

Damaged or restricted air

lines

Replace damaged air line or remove restriction

Low Air pressure

Minimum 80 Psi required at regulator, if lower check

air supply.

Dock leveler binding

Check for visible obstructions that could cause

binding. Remove obstructions. If no obstructions

found, call Poweramp

®

Technical Services.

Platform does not rise to

full height.

See Platform Rises Slowly

See Platform Rises Slowly

See Periodic Maintenance in the Maintenance

section.

Low Air pressure

Minimum 80 Psi required at regulator, if lower check

air supply.

Platform DOES rise to

full height, but lip DOES

NOT extend or extend

fully.

Lip actuator spring needs

additional tension.

Inspect lip actuator chain, repair or replace as

needed.

Lip extends but does

not remain extended as

leveler drops.

Lip latch spring needs

additional tension.

See Adjustment Section: Lip Latch Spring.

• Increase tension as needed to keep latch

engaged.

• Clean any debris from lip latch area.

• Lubricate as instructed in maintenance section.