Page 10

 

• The unit is successfully installed and functioning properly.

4. UNIT

OPERATION

Auto Backup Mode (Factory Default Setting)

The unit is fully automatic. When utility power is available, the unit is running in AC bypass mode.
AC output is supplied from the utility. The internal AC charger is ON and will automatically top up
the battery bank that is connected to the unit. When there is a power failure from the utility or an
AC source is not available, the unit will run on battery power and the unit will generate sinewave
AC output to maintain and operate the load continuously.

Factory Default Setting

Charger On
Inverter On
SCR set

30A

Power Save

Off

Battery Type

AGM

Set Current

150A

EQ Mode

Off

Fault Alarm

On

Display Background Brightness

80%

Background Light Timer

3 minutes

Non-Backup Mode

Same as Auto Backup Mode but when there is a power failure of the utility or the AC input source
is not available, the inverter will not turn ON automatically. You are required to manually turn ON
the inverter. This setting is the same as factory default but with Inverter set to OFF.

Understanding the Display Functions

LED Indicator functions on unit display and remote display:

Status Display

Function/Status

Battery
Power

Green
LED
ON
(solid)

Battery Power Mode. Remote LCD Display shows:
- Battery DC Voltage and Current
- Inverter AC Output Voltage and Current
e.g. DC: 12.5V 30A AC: 120V 2.7A
Press ‘+’ or ‘-‘ key to check AC Output Power.
e.g. System Power 0.33 KW

Charging Green

LED
ON
(solid)

Pass-Through Mode. Battery is fully charged. Remote LCD
Display shows:

- AC Input Voltage and Current
- Battery DC Voltage and charging current

e.g. AC: 120V 15A DC: 12.0V 5A
Press ‘+’ or ‘-‘ key to check charging stage.
e.g. Charge Stage Float
Press ‘+’ or ‘-‘ key to check AC Input Power.
e.g. System Power 1.80 KW