Estimated Run Times

Following run times are estimates for reference, based on using different battery bank sizes.
Actual run times may vary.

Estimate run time on different 12V Battery Bank Size

AC Load

60AH 120AH 180AH 240AH 300AH

50 W

11 hrs.

22 hrs.

33 hrs.

44 hrs.

55 hrs.

100 W

5 hrs.

11.5 hrs.

17 hrs.

23 hrs.

29 hrs.

200 W

2.5 hrs.

5 hrs.

8 hrs.

11 hrs.

13.5 hrs.

500 W

49 mins

2 hrs.

3 hrs.

4 hrs.

5 hrs.

1000 W

15 mins

49 mins

1.5 hrs.

2 hrs.

2.5 hrs.

1500 W

8 mins

27 mins

49 mins

1 hr

1.5 hrs

2000 W

N.R.

15 mins

34 mins

49 mins

1 hrs

2500 W

N.R.

11 mins

25 mins

37 mins

49 mins

3000 W

N.R.

N.R.

17 mins

27 mins

37 mins

Note: N.R. – Not Recommended

5. FEATURE

SETTING

To understand more about the unit features, read the following section and follow the instructions
to make changes to the desired setting.

Feature Menu for Unit Setting

To enter feature setting mode, on remote display, press and hold ‘EXIT’ button for 5 seconds.
The feature setting menu will display on the screen with the following sequence:

Menu Sequence

Setting

Function

Charger

On/Off

Turns Battery Charger On/Off

Inverter

On/Off

Turns Power Inverter On/Off

SCR set

15, 20,25,30 A

Set AC Input Source Power Breaker Rating.
During by-pass mode with high demand for
AC power for the load, the charger current is
reduced automatically to prevent the tripping
of the AC Source power breaker.

Power Save

0, 5, 10, 15, 20, 50W

Lowers power draw when low power loads are
connected to inverter

Battery Type

AGM, GEL, Flooded

Select battery type

Set Current

60 – 150A (5A step)

Set charger current

EQ Mode
(Flooded battery
type use only)

On/Off

EQ mode is used to equalize the flooded
battery. The charging voltage is 16V and the
current is set to half the set bulk current for 1
hour (min: 30A, Max: 75A).

Fault Alarm

On/Off

Silent mode: Enable or Disable the audible
alarm when fault occur

Brightness

10-100% (10% step)

Set LCD Background lighting brightness

Backlight Timer

1–9 mins (1 min step)

Set timer ON for LCD background lighting

Use the ‘+’ and ‘-‘ button to scroll between feature setting menu.
Press ‘ENTER’ button to go to the selected feature and you can now make changes on the
selected feature to your desired setting.
Use the ‘+’ and ‘-‘ button to scroll between different set values or setting. Once the desired values
or setting is chosen, press ‘ENTER’ button to save the setting or press ‘EXIT’ button to quit the