DIMENSIONS:

MX-250 Height: 36” Width: 46” Depth: 48”

Weight: 630 LBS

MX-300 Height: 36” Width: 46” Depth: 48”

Weight: 630 LBS

FIRING CAPACITIES:

MX-250

Nozzle @ 1.79 gallons/hour, No. 2 fuel oil/used crankcase oil

MX-300

Nozzle @ 2.14 gallons/hour, No. 2 fuel oil/used crankcase oil

MINIMUM CLEARANCE TO COMBUSTIBLES:

Top . . . . . . . . . . . . . . . . . . . . . . . . 6”

Chimney Connector . . . . .18”

Sides . . . . . . . . . . . . . . . . . . . . . 18”

Rear . . . . . . . . . . . . . . . . . . . . . 6”

Burner Side . . . . . . . . . . . . . . . 38”
Front . . . . . . . . . . . . . . . . . . . . . 60”

Bottom . . . . . . . . . . . . . . . . 24”

THIS HEATER IS DESIGNED TO BURN THE FOLLOWING APPROVED FUELS:

Used 5W through 50W Crankcase Oils
No. 1 and No. 2 Fuel Oils

s

s This heater is not designed for attachment or use with ductwork.

s Do not attempt to start the burner when excess oil, oil vapor, or fumes have
accumulated! Never press the red button on the oil primary control more than
twice! This could cause excess vapor, or fuel to ignite causing damage to the
heater and/or chimney.

s Do not store or use gasoline, or any other FLAMMABLE liquid and/or Vapors near this

heater.

s This heater is not designed for use in hazardous atmospheres such as: 0aint Shops, Feed

Mills, installations

WHEre explosiVe or FLAMMABLE conditions are present or could occur.

WARNING!

Lanair heaters rely on natural draft. Do

WN drafts (positiVe pressures)

in the heaters chimney

WILL occur in BUILDINGS WHEre negatiVe pressures are created

By exhaust fans, (car exhaust, paint BOOTHs, etc). Do not try to use a poWer Vent to
o

Vercome a doWN draft (positiVe pressure). An adequate make-up air system is

required

WHEN exhaust fans are used (consult your heating contractor).

!