14

17. If you are unable to attain the proper draft, check for exhaust fans in the building. To test

if there is a problem, open an overhead door and see if you now have the proper draft.
You may have to add one or more sections of “Class A” chimney to the roof to get the
proper draft.

18. The heater and chimney must be installed in accordance with all state and local

codes. The heater must be installed in accordance with the specifications listed in
this manual. The chimney must be installed per the chimney manufacturer’s
instruction. Use “Class A” chimney only.

Chimney Configurations Using Top Vent ( not to scale )

Left Exhaust
Through Roof

Right Exhaust

Through Wall

Right Exhaust
Through Roof

Left Exhaust

Install Cap

On Vent

Install Cap

On Vent

Install Cap

On Vent

Install Cap

On Vent