Lanair MX300 User Manual

Page 12

Advertising
background image

Section 2 - Heater Install w/ Metering Pump

10b

Class “A” Chimney

Barometric Damper

2-3 ft. away from heater

Ceiling Hung

8 ft. min.

10 ft. max.

Secondary Air Regulator

Primary Air Regulator (not supplied)

Set to 30 lbs.

Chimney Connector

10 foot max. length

1/4” rise per foot of length

Chimney Cap

3 ft. taller than

any object within 10 ft.

10 ft.

min.

Fuel Line - 1/2” O.D.

Soft Copper

Room
Thermostat

Service
Disconnect

Main Power
120v - 60 hz 20 amp

Metering Pump

Primary Strainer

1/2” Checkvalve
and Oil
Strainer

Supply Tank

16

17

19

20

23

14

24

13

12

13

18

11

10

9

2

5

1

15

21

22

8

8

11

3

4

6

7

1. Chimney Cap
2. Chimney Pipe (36”)
3. Storm Collar
4. Roof Flashing
5. Chimney Pipe (36")
6. Finishing Collar
7. Slip Connector (14")
8. Black Pipe (24")
9. Black Tee w/cap

10. Barometric Damper
11. Black Pipe (24")
12. Burner
13. Union
14.
15.
Shut-off Valve
16. Shut-off Valve
17. Suction Line Strainer
18. Fuel Pump

19. Check Valve
20. Pick-up Tube Strainer
21. Thermostat
22. Service Disconnect
23. Tank Drain
24. Fill Pipe

Tank Vent

★ Included with Heater

TYPICAL INSTALLATION:

HEATER/CHIMNEY PACKAGE

Through the roof installation

Figure 1

QUESTIONS?... Contact Customer Service at 1-888-370-6531 M-F 8:00 am- 4:15 pm CST