Section 10 - Priming The Fuel Pump

QUESTIONS?... Contact Customer Service at 1-888-370-6531 M-F 8:00 am- 4:15 pm CST

26

12. Turn the room thermostat below room temperature or “OFF”. The fuel supply pump will

now stop.

13. Reconnect the fuel supply line to the burner.

14. Remove the jumper wire from the F-F terminals on the oil primary control, reattach the

yellow cad cell wires.

15. Adjust the burner air filter/regulator to 18 PSI.

16. If the fuel supply pump prime, or fuel stream has air in it (spurting, fluctuating flow) there

is likely a leak in the suction side of the plumbing. Refer to section 14, trouble-shooting,
flow chart #2. The burner should now be ready to fire.