MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box

11

MVP-WDS Wall Docking Station for MVP Panels

6.

Tighten all four drywall clip sets (screws and clips) until both Mounting Tabs are securely fastened
and flush against the wall.

7.

Follow the steps outlined in the Replacing the Faceplate on the MVP-WDS section on page 13 to
angle the MVP Support Cradle forward and re-install the faceplate.

Installing the MVP-WDS Into a Flat Surface Using Mounting Screws

Use #4-40 Mounting screws (not included) to mount the WDS to a flat surface, through the two sets of
holes located on the sides of the WDS.

Refer to SP-5965-01 for detailed installation dimensions (reproduced in FIG. 13).

It is recommended that you cutout the surface slightly smaller than what is outlined in the
installation drawings so that you can make any necessary cutout adjustments.

The outer frame Mounting Tabs must be installed so that they are flush against the mounting
surface.

1.

Cut out the surface for the MVP-WDS docking station using the dimensions shown in FIG. 13.

FIG. 12

MVP-WDS installation configuration for drywall surfaces

B - MVP-WDS (Main unit)

Install the four

included drywall clip sets

Four notches are required

A - Faceplate

Mounting Tab

Die Cut Foam

covers (2)

at these locations

to accommodate the four
expansion clips (included)

#6-32 Faceplate

Security Screws (2)

Replacement drywall clip sets cab be ordered from AMX.