AMX Wall Docking Station MVP-WDS User Manual

Page 18

Advertising
background image

MVP-WDS Wall Docking Station & CB-MVPWDS Rough-In Box

12

MVP-WDS Wall Docking Station for MVP Panels

2.

Thread the USB and Power cables through the surface opening, leaving enough slack in the wiring
to accommodate any re-positioning of the unit.

3.

Connect the 2-pin power connector and USB cables along the right side of the (un-powered)
MVP-WDS. The faceplate must be removed prior to any surface installation.

Verify that the terminal end of the power cable is not connected to a power source before
plugging in the 2-pin power connector.

The USB connectors can be from either a USB extension cable, or a wireless USB RF
transmitter.

4.

Test the Power and USB connections before fully installing the WDS. Refer to the LED
Indicators table on page 3
for blink pattern information.

5.

Disconnect the terminal end of the power cable from the connected power supply.

6.

Carefully insert the main unit into the cutout until the Mounting Tabs on the MVP-WDS lie flush
against the wall (FIG. 14).

FIG. 13

MVP-WDS Wall Mount cutout dimensions using solid surface screws

R.13 [3.2MM] MAX RADIUS IN 4 CORNERS

CUTOUT

FRONT BEZEL OUTLINE

11.06 [281MM]

12.70 [323MM] BEZEL OUTLINE

THESE 4 HOLES ARE ONLY REQUIRED

WHEN MOUNTING UNIT TO A SOLID

SURFACE (PODIUM, DESK, ETC).

SECURE UNIT WITH #4 SCREWS

8.63 [219MM]

BEZEL OUTLINE

12.10 [307MM]

1.19 [30MM] TYP

5.54 [141MM]

.52 [13MM] TYP

7.91 [201MM]

Don’t disconnect the PWR and USB connectors from the MVP-WDS. The unit must
be installed with these attached.

Applying power to the MVP-WDS causes the MVP Support Cradle to retract back into
docking station.