SecurityMan Air-AlArm1 - User manual User Manual

Page 15

Advertising
background image

12

installation and Usage

Mount the bracket to a desired wall surface, location, or corner at a height of about 6ft to 7ft above the ground.

Open the sensor cover and connect a 9VDC battery. Next, refers to the diagrams above to adjust and select the Jumper Line timer between

5S or 5MIN for the motion sensor to detect once every 5 seconds or the sensor to detect once every 5 minutes. Recommended to use

“5S”

default “setting for normal use. Skip “To Add” motion sensor below for newly added motion sensor before closing the sensor cover and
proceed to the next step.
Match the grooves of the sensor to the bracket and slide the motion sensor down from top to bottom to secure.

Adjust the sensor to a proper angle and then slide the power switch located on the side to the “ON” position. The motion sensor takes 30

seconds to become active for operation (normal working state) after switching “ON”.
A red light will flash for motion detection, a frequent green light flashing means it is time to replace the battery.

Adding and Cancelling Pir motion sensor

To Add:

Press_

set + Password + eNt_then.

_

70 + eNt+ XX + eNt

The “Learn” light will appear solid red.

Note: the “XX” indicate group number of the 2nd defense zones, including zone 11 through zone 15.

Press the “Learning Emitting Switch” twice consecutively to trigger PIR sensor, the alarm host will beep in series, and the “Learn” light flashes

five times and then turns off to indicate the PIR motion sensor has been successfully added.

To Cancel:

Press_

set + Password + eNt_then.

_

71 + eNt+ XX + eNt

The alarm host will beep twice then the “Learn” light flashes once and then turns off to indicate the PIR

motion sensor has been successfully cancelled.

Note: the alarm host can only learn 1 wireless device (Wireless Wide-Angle Pir motion sensor) at a time, a total of 4 wireless devices (Pir
motion sensors) to a zone/group can be added. for example; for the 2st defense line, if 4 sensors were to be added to zone/group 11
through zone / group 15, it total 20 sensors in all. if 1 device is removed from a group that has 4 devices, then all 4 devices in the group will
be automatically removed, and each device(s) will have to be added again to the alarm host.

Advertising